The Delock 11827 switchable power outlet is not calibrated by default. You can calibrate it yourself very quickly as follows:

 

 

 

You’ll need a light bulb (e.g., 60W) and a power meter that displays the exact power (W) and voltage (V). If you don’t have one, you’ll need a multimeter to measure the voltage (V).

Next, turn on the 11827 with the power meter and the light bulb connected, and read the power (W) and voltage (V).

In the console, enter VoltageSet <measured voltage> and PowerSet <measured power>. Afterward, the power factor should display 1.0 or be very close to 1.0. Otherwise, the calibration should be performed again.

If you do not have a power meter, use the wattage printed on the light bulb (e.g., 60) and the voltage measured with the multimeter. Of course, this means the calibration will not be 100% accurate.